RF Output Connector:
3 1/8 Inch EIA, 50 ohms
Frequency Range: 87.5MHz to 108MHz programmable
in 10kHz steps
Frequency Stability: ± 150 Hz, 0° to 50°C using
high accuracy internal
(59.535MHz) TCXO. 10MHz input for synchronization to
external (GPS) reference.
Automatic switching to internal oscillator if
external reference fails.
Overall Efficiency: HD mode greater than or
equal to 26% AC to RF, FM+HD
(common mode-20dB ratio) mode greater than or equal
to 37% AC to RF, FM
(analog only) mode greater than or equal to 55% AC
to RF. All figures are at model
specific nominal output power.
Harmonic / Spurious Suppression: Internal
harmonic filter meets or exceeds all
FCC, IC, CE, CCIR and IEC215 requirements. Meets or
exceeds standard NRSC-5A
emission limits in all modes.
VSWR: For load VSWR exceeding 1.5:1, nominal,
transmitter automatically reduces
RF output as a function of load VSWR (proportional
VSWR foldback). For an instantaneous
VSWR of 3:1 or greater, an automatic carrier
interruption occurs to extinguish
possible arcing conditions in the output load.
Modulation Types: FM digitally synthesized
direct to channel, HD digital direct to
channel, FM+HD digital direct to channel.
Operating Modes: “On-the-Fly” switching between
FM only, HD only, FM+HD.
FM Modulation Capability: Greater than ± 300
kHz.
Asynchronous AM S/N Ratio: 55dB minimum below
equivalent 100% amplitude
modulation by 400Hz using 75μs de-emphasis (no FM
modulation present).
Synchronous AM S/N Ratio: 50dB minimum below
equivalent 100% amplitude
modulation with 75μs de-emphasis and 400Hz high-pass
filter (FM deviation +/-
75kHz by a 1kHz sine wave). Measured at wideband
input.
AC Mains Requirement:
197 to 250V, 3-phase, 50 or 60Hz, 3-wire Closed
Delta or WYE
RF Cabinet Size: 28.6” (72.6cm) W x 49.72” (
126.3cm) D x 72” (183cm) H (with
fan and air filter assembly attached)
Harmonic/Low Pass Filter: Internal
Remote Control Connections: Barrier strip inside
upper left sidewall (facing rear of
transmitter)
Additional Remote Control Connection: RS-232 on
system controller supports
eCDI or WebRemote
AC Entrances: Through top or bottom surface of
cabinet
Fuse/Breaker: Wall-mounted fused disconnect or
breaker is customer-supplied item.
An RK5 class fuse such as the Bussman FRN-R(250V),
FRS-R (600V) or LittleFuse FLNR
(250V), FLSR (600V) is recommended. If a circuit
breaker is used it should have a trip
curve similar to that of the RK5 fuse trip curve
AC Power Factor: 3-phase: 0.95; 1-phase: 0.8